Sequoyah Nuclear Plant Moisture Separator Reheater Project
Report Information
Recommendations
We recommend the Senior Vice President and Chief Nuclear Officer, initiate actions to evaluate the quality of the moisture separator reheaters to determine usability.
We recommend the Senior Vice President and Chief Nuclear Officer, take steps to have quality issues and corrective actions with the Sequoyah Nuclear Plant Moisture Separator Reheater Project documented in the corrective action program.
We recommend the Senior Vice President and Chief Nuclear Officer, initiate a review to determine why the issues were not documented in the corrective action program in a timely manner.
We recommend the Vice President, Projects and Outages, coach project managers on the importance of obtaining input from appropriate personnel and only taking actions they are authorized to perform when making contracting decisions.
We recommend the Vice President, Projects and Outages, coach project managers on the importance of reviewing invoices thoroughly and obtaining input from contracting officers to identify potential unauthorized expenses before approval.